Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Inhalation exposure to particulate matter in rooms with underfloor air distribution
This work investigated the personal exposure to indoor particulate matters using the intake fraction metric and provided a possible way to trace the particle inhaled from an indoor particle source. A turbulence model validated by the particle measurements in a room with underfloor air distribution (UFAD) system was used to predict the indoor particle concentrations. Inhalation intake fraction of indoor particles was defined and evaluated in two rooms equipped with the UFAD, i.e., the experimental room and a small office. According to the exposure characteristics and a typical respiratory rate, the intake fraction was determined in two rooms with a continuous and episodic (human cough) source of particles, respectively. The findings showed that the well-mixing assumption of indoor air failed to give an accurate estimation of inhalation exposure and the average concentration at return outlet or within the overall room could not relate well the intake fraction to the amount of particle emitted from an indoor source.
Inhalation exposure to particulate matter in rooms with underfloor air distribution
This work investigated the personal exposure to indoor particulate matters using the intake fraction metric and provided a possible way to trace the particle inhaled from an indoor particle source. A turbulence model validated by the particle measurements in a room with underfloor air distribution (UFAD) system was used to predict the indoor particle concentrations. Inhalation intake fraction of indoor particles was defined and evaluated in two rooms equipped with the UFAD, i.e., the experimental room and a small office. According to the exposure characteristics and a typical respiratory rate, the intake fraction was determined in two rooms with a continuous and episodic (human cough) source of particles, respectively. The findings showed that the well-mixing assumption of indoor air failed to give an accurate estimation of inhalation exposure and the average concentration at return outlet or within the overall room could not relate well the intake fraction to the amount of particle emitted from an indoor source.
Inhalation exposure to particulate matter in rooms with underfloor air distribution
Gao, Jun (Autor:in) / Cao, Changsheng (Autor:in) / Luo, Zhiwen (Autor:in) / Zhang, Xu (Autor:in)
Indoor and Built Environment ; 23 ; 236-245
01.04.2014
10 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Inhalation exposure to particulate matter in rooms with underfloor air distribution
Online Contents | 2014
|Engineering Index Backfile | 1949
Outlook for underfloor air distribution
Tema Archiv | 2001
|UNDERFLOOR REINFORCEMENT METHOD AND UNDERFLOOR REINFORCEMENT STRUCTURE
Europäisches Patentamt | 2023
|UNDERFLOOR WIRING STRUCTURE AND UNDERFLOOR WIRING METHOD
Europäisches Patentamt | 2024
|