Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
A case study of acoustic intervention in classrooms
High reverberation times (RTs) have always been an acoustic barrier to effective learning in classrooms. Acoustic corrections to reduce RT involve complex acoustic treatment. Previous studies have indicated that classrooms in most schools do not meet the established acoustic criteria, as the school authorities refrain from such acoustic treatment. Aim of the study was to optimize the RT within classrooms through easily-implementable acoustic corrections. Different combinations of acoustic corrections have been experimented in eight classrooms, through a step-by-step approach to optimize RT. After each acoustic modification, the RT was measured and the speech clarity parameter C50, was estimated. At the final step, RT of the classrooms was diminished to a mean value of 0.74 s (standard deviation = 0.04) from the initial mean value of 4.37 s (standard deviation = 0.42). C50 values corresponding to the final acoustic correction were found to fall within good speech intelligibility scale.
A case study of acoustic intervention in classrooms
High reverberation times (RTs) have always been an acoustic barrier to effective learning in classrooms. Acoustic corrections to reduce RT involve complex acoustic treatment. Previous studies have indicated that classrooms in most schools do not meet the established acoustic criteria, as the school authorities refrain from such acoustic treatment. Aim of the study was to optimize the RT within classrooms through easily-implementable acoustic corrections. Different combinations of acoustic corrections have been experimented in eight classrooms, through a step-by-step approach to optimize RT. After each acoustic modification, the RT was measured and the speech clarity parameter C50, was estimated. At the final step, RT of the classrooms was diminished to a mean value of 0.74 s (standard deviation = 0.04) from the initial mean value of 4.37 s (standard deviation = 0.42). C50 values corresponding to the final acoustic correction were found to fall within good speech intelligibility scale.
A case study of acoustic intervention in classrooms
Abraham, Ajish K (Autor:in) / Ravishankar, M S (Autor:in)
Building Acoustics ; 28 ; 293-308
01.12.2021
16 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Acoustic, thermal and luminous comfort in classrooms
British Library Online Contents | 2004
|Acoustic, thermal and luminous comfort in classrooms
Online Contents | 2004
|Effectiveness of ventilation system in classrooms : a case study
British Library Conference Proceedings | 1994
|Case Study: The Acoustical Characteristics of Typical Argentinean Classrooms
SAGE Publications | 2001
|A field study on the acoustic environment of special-needs education classrooms
SAGE Publications | 2019
|