Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Connection Design
Abstract The joints and connections are the main component in steel structures to transfer the loads between structural components and provide integrity for structure. Design of joints in steel structure is mainly focus on determining of welding properties and connection bolt details to provide enough strength, shear and tension resistance for the joint to transfer the considered loads. Different connections such as column to column joint, beam to beam joint and beam to column joint alter the flexibility of joints and thus affect the behaviour of the entire steel frame system. This chapter outlines the connection design procedure, which included welded and bolted connection. Configuration of connection is based on the desired support condition of connected beams and columns. Detailed configuration, mainly the spacing between bolts should strictly conform to the EuroCode 3 requirements. Also, calculation of support reaction for the beams and columns determines the force acting on the joints. The evaluation of connection configuration with its resistance is done with the aids of tables and equations as per EuroCode3.
Connection Design
Abstract The joints and connections are the main component in steel structures to transfer the loads between structural components and provide integrity for structure. Design of joints in steel structure is mainly focus on determining of welding properties and connection bolt details to provide enough strength, shear and tension resistance for the joint to transfer the considered loads. Different connections such as column to column joint, beam to beam joint and beam to column joint alter the flexibility of joints and thus affect the behaviour of the entire steel frame system. This chapter outlines the connection design procedure, which included welded and bolted connection. Configuration of connection is based on the desired support condition of connected beams and columns. Detailed configuration, mainly the spacing between bolts should strictly conform to the EuroCode 3 requirements. Also, calculation of support reaction for the beams and columns determines the force acting on the joints. The evaluation of connection configuration with its resistance is done with the aids of tables and equations as per EuroCode3.
Connection Design
Hejazi, Farzad (Autor:in) / Chun, Tan Kar (Autor:in)
01.01.2018
29 pages
Aufsatz/Kapitel (Buch)
Elektronische Ressource
Englisch
NTIS | 1987
|Australian Connection Design Methods
British Library Conference Proceedings | 1999
|United Kingdom Connection Design
British Library Conference Proceedings | 1999
|Debating Steel-Connection Design
British Library Online Contents | 1994
|Detailing and connection design
Tema Archiv | 2001
|