Near-black or dark brown roofing membranes can develop surface temperatures of over 95°C when applied as a finish over thermally insulated flat roofs, the author reports and recommends that lighter surface colours should be considered.
Near-black or dark brown roofing membranes can develop surface temperatures of over 95°C when applied as a finish over thermally insulated flat roofs, the author reports and recommends that lighter surface colours should be considered.
Surface and inner temperature attainment of flat roof systems in hot-dry climate
Ozkan, E. (Autor:in)
Building Research & Information ; 21 ; 25-35
01.01.1993
11 pages
Aufsatz (Zeitschrift)