A platform for research: civil engineering, architecture and urbanism
Near-black or dark brown roofing membranes can develop surface temperatures of over 95°C when applied as a finish over thermally insulated flat roofs, the author reports and recommends that lighter surface colours should be considered.
Near-black or dark brown roofing membranes can develop surface temperatures of over 95°C when applied as a finish over thermally insulated flat roofs, the author reports and recommends that lighter surface colours should be considered.
Surface and inner temperature attainment of flat roof systems in hot-dry climate
Ozkan, E. (author)
Building Research & Information ; 21 ; 25-35
1993-01-01
11 pages
Article (Journal)
Electronic Resource
English
Flat roof systems and methods for constructing flat roof systems
European Patent Office | 2019
|Thermal Performance of Bamboo Flat Roof Slab and RCC Flat Roof Filler Slab in Warm-Humid Climate
Springer Verlag | 2023
|Emerald Group Publishing | 1988
|