Comparison of ASHRAE peak cooling load calculation methods
The building peak cooling load calculation is one of the fundamental steps to develop a proper whole-building HVAC system design. The accuracy of the calculation not only impacts the system size but also influences the building’s performance over the long run since oversized or undersized HVAC systems can exhibit less than optimal operation. Therefore, an accurate, easy-to-use method has been a goal for more than 60 years in the United States. To date, ASHRAE has published five methods for determining building peak cooling loads, including the total equivalent temperature difference/time averaging (TETD/TA) method, the transfer function method (TFM), the cooling load temperature difference/solar cooling load/cooling load factor (CLTD/SCL/CLF) method, the heat balance method (HBM), and the radiant time series method (RTSM). This article presents the results of a comprehensive comparison of these building peak cooling load calculation methods with a focus on the sensible building envelope cooling loads. The results show that the HBM is the most accurate method, followed by the RTSM, the TFM, the TETD/TA method, and the CLTD/SCL/CLF method.
Comparison of ASHRAE peak cooling load calculation methods
The building peak cooling load calculation is one of the fundamental steps to develop a proper whole-building HVAC system design. The accuracy of the calculation not only impacts the system size but also influences the building’s performance over the long run since oversized or undersized HVAC systems can exhibit less than optimal operation. Therefore, an accurate, easy-to-use method has been a goal for more than 60 years in the United States. To date, ASHRAE has published five methods for determining building peak cooling loads, including the total equivalent temperature difference/time averaging (TETD/TA) method, the transfer function method (TFM), the cooling load temperature difference/solar cooling load/cooling load factor (CLTD/SCL/CLF) method, the heat balance method (HBM), and the radiant time series method (RTSM). This article presents the results of a comprehensive comparison of these building peak cooling load calculation methods with a focus on the sensible building envelope cooling loads. The results show that the HBM is the most accurate method, followed by the RTSM, the TFM, the TETD/TA method, and the CLTD/SCL/CLF method.
Comparison of ASHRAE peak cooling load calculation methods
Mao, Chunliu (Autor:in) / Baltazar, Juan-Carlos (Autor:in) / Haberl, Jeff S. (Autor:in)
Science and Technology for the Built Environment ; 25 ; 189-208
07.02.2019
20 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Comparison between ASHRAE and ISO thermal transmittance calculation methods
Online Contents | 2007
|Electronic Tables for the ASHRAE Load Calculation Manual (RP-626)
British Library Online Contents | 1993
|Taylor & Francis Verlag | 2023
|Overview of the Ashrae Annotated Guide to Load Calculation Models and Algorithms
British Library Online Contents | 1995
|Comparative Analysis of CIBSE Admittance and ASHRAE Radiant Time Series Cooling Load Models
DOAJ | 2022
|