Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Loss of Particle Nitrate from Teflon Sampling Filters: Effects on Measured Gravimetric Mass in California and in the IMPROVE Network
The extent of mass loss on Teflon filters caused by ammonium nitrate volatilization can be a substantial fraction of the measured particulate matter with an aerodynamic diameter less than 2.5 μm (PM2.5)or 10 μm (PM10) mass and depends on where and when it was collected. There is no straightforward method to correct for the mass loss using routine monitoring data. In southern California during the California Acid Deposition Monitoring Program, 30-40% of the gravimetric PM2.5 mass was lost during summer daytime. Lower mass losses occurred at more remote locations. The estimated potential mass loss in the Interagency Monitoring of Protected Visual Environments network was consistent with the measured loss observed in California. The biased mass measurement implies that use of Federal Reference Method data for fine particles may lead to control strategies that are biased toward sources of fugitive dust, other primary particle emission sources, and stable secondary particles (e.g., sulfates). This analysis clearly supports the need for speciated analysis of samples collected in a manner that preserves volatile species. Finally, although there is loss of volatile nitrate (NO3 −) from Teflon filters during sampling, the NO3 − remaining after collection is quite stable. We found little loss of NO3 − from Teflon filters after 2 hr under vacuum and 1 min of heating by a cyclotron proton beam.
Loss of Particle Nitrate from Teflon Sampling Filters: Effects on Measured Gravimetric Mass in California and in the IMPROVE Network
The extent of mass loss on Teflon filters caused by ammonium nitrate volatilization can be a substantial fraction of the measured particulate matter with an aerodynamic diameter less than 2.5 μm (PM2.5)or 10 μm (PM10) mass and depends on where and when it was collected. There is no straightforward method to correct for the mass loss using routine monitoring data. In southern California during the California Acid Deposition Monitoring Program, 30-40% of the gravimetric PM2.5 mass was lost during summer daytime. Lower mass losses occurred at more remote locations. The estimated potential mass loss in the Interagency Monitoring of Protected Visual Environments network was consistent with the measured loss observed in California. The biased mass measurement implies that use of Federal Reference Method data for fine particles may lead to control strategies that are biased toward sources of fugitive dust, other primary particle emission sources, and stable secondary particles (e.g., sulfates). This analysis clearly supports the need for speciated analysis of samples collected in a manner that preserves volatile species. Finally, although there is loss of volatile nitrate (NO3 −) from Teflon filters during sampling, the NO3 − remaining after collection is quite stable. We found little loss of NO3 − from Teflon filters after 2 hr under vacuum and 1 min of heating by a cyclotron proton beam.
Loss of Particle Nitrate from Teflon Sampling Filters: Effects on Measured Gravimetric Mass in California and in the IMPROVE Network
Ashbaugh, Lowell L. (Autor:in) / Eldred, Robert A. (Autor:in)
Journal of the Air & Waste Management Association ; 54 ; 93-104
01.01.2004
12 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
A Comparison of Four Gravimetric Fine Particle Sampling Methods
Taylor & Francis Verlag | 2001
|Taylor & Francis Verlag | 1999
|Buoyancy-Corrected Gravimetric Analysis of Lightly Loaded Filters
Taylor & Francis Verlag | 2010
|Loss of PM2.5 Nitrate from Filter Samples in Central California
Taylor & Francis Verlag | 2005
|Control of Organic Artifact on Teflon Filters by Quality Assurance Procedures
British Library Conference Proceedings | 1992
|