Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Experimental Research on Fireproofing Measure of Beams Strengthened by Carbon Fiber Sheet Bonded with Inorganic Adhesive
Because of high temperature above 1000 °C on fire, and Oxidation of carbon fiber at high temperature, fireproofing measure should be make to take advantage of the inorganic adhesive for beams strengthened by carbon fiber sheet bonded with the adhesive. The problem of which fireproofing material should be choose and how to make fireproofing measure needs to resolve. Fireproofing test is make for beams strengthened by carbon fiber sheet bonded with the adhesive protected by Thick-typed Fireproof Coating for steel structure (TFCSS) and Thick-typed Fireproof Coating for tunnel (TFCT). Typical damage state of the two typical coating is compared on and after fire, Temperature field of specimen is analyzed, and fireproofing effect is compared. The test results indicate that, under the protection of fireproof coating with proper structure, TFCT and TFCSS can supply effective fireproofing protection for carbon fiber sheet, but the former is inferior to the latter because the latter is easier to drop and crack in fire.
Experimental Research on Fireproofing Measure of Beams Strengthened by Carbon Fiber Sheet Bonded with Inorganic Adhesive
Because of high temperature above 1000 °C on fire, and Oxidation of carbon fiber at high temperature, fireproofing measure should be make to take advantage of the inorganic adhesive for beams strengthened by carbon fiber sheet bonded with the adhesive. The problem of which fireproofing material should be choose and how to make fireproofing measure needs to resolve. Fireproofing test is make for beams strengthened by carbon fiber sheet bonded with the adhesive protected by Thick-typed Fireproof Coating for steel structure (TFCSS) and Thick-typed Fireproof Coating for tunnel (TFCT). Typical damage state of the two typical coating is compared on and after fire, Temperature field of specimen is analyzed, and fireproofing effect is compared. The test results indicate that, under the protection of fireproof coating with proper structure, TFCT and TFCSS can supply effective fireproofing protection for carbon fiber sheet, but the former is inferior to the latter because the latter is easier to drop and crack in fire.
Experimental Research on Fireproofing Measure of Beams Strengthened by Carbon Fiber Sheet Bonded with Inorganic Adhesive
Wan, Fu-Xiong (Autor:in)
2013
5 Seiten
Aufsatz (Konferenz)
Englisch
British Library Conference Proceedings | 2014
|British Library Conference Proceedings | 2012