Experimental Research on Fireproofing Measure of Slabs Strengthened by Carbon Fiber Sheet Bonded with Inorganic Adhesive
Because of high temperature above 1000 °C on fire, and Oxidation of carbon fiber at high temperature, fireproofing measure should be make to take advantage of inorganic adhesive for slabs strengthened by carbon fiber sheet bonded with the adhesive. The problem of which fireproofing material should be choose and how to make fireproofing measure needs to resolve. Fireproofing test is make for slabs strengthened by carbon fiber sheet bonded with the adhesive protected by Thick-typed Fireproof Coating for steel structure (TFCSS) and Thick-typed Fireproof Coating for tunnel (TFCT). Typical damage state of the two typical coating is compared during and after fire, Temperature field of slab specimen is analyzed, and fireproofing effect is compared. The test results indicate that, steel wire mesh in the middle of coating layer can prevent coating from falling fully, so steel wire mesh is necessary for fireproofing coat which is not too thick. under the protection of fireproof coating with proper construction, TFCT and TFCSS can supply effective fireproofing protection for carbon fiber sheet, but the former is inferior to the latter because the latter is easier to drop and crack in fire. So, TFCT with steel wire mesh can supply the most effective protection for slabs strengthened by carbon fiber sheet bonded with the adhesive.
Experimental Research on Fireproofing Measure of Slabs Strengthened by Carbon Fiber Sheet Bonded with Inorganic Adhesive
Because of high temperature above 1000 °C on fire, and Oxidation of carbon fiber at high temperature, fireproofing measure should be make to take advantage of inorganic adhesive for slabs strengthened by carbon fiber sheet bonded with the adhesive. The problem of which fireproofing material should be choose and how to make fireproofing measure needs to resolve. Fireproofing test is make for slabs strengthened by carbon fiber sheet bonded with the adhesive protected by Thick-typed Fireproof Coating for steel structure (TFCSS) and Thick-typed Fireproof Coating for tunnel (TFCT). Typical damage state of the two typical coating is compared during and after fire, Temperature field of slab specimen is analyzed, and fireproofing effect is compared. The test results indicate that, steel wire mesh in the middle of coating layer can prevent coating from falling fully, so steel wire mesh is necessary for fireproofing coat which is not too thick. under the protection of fireproof coating with proper construction, TFCT and TFCSS can supply effective fireproofing protection for carbon fiber sheet, but the former is inferior to the latter because the latter is easier to drop and crack in fire. So, TFCT with steel wire mesh can supply the most effective protection for slabs strengthened by carbon fiber sheet bonded with the adhesive.
Experimental Research on Fireproofing Measure of Slabs Strengthened by Carbon Fiber Sheet Bonded with Inorganic Adhesive
Wan, Fu-Xiong (Autor:in)
2014
5 Seiten