Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Experimental study of the fire resistance of walls and floors constructed with steel studs and steel joists
Steel‐framed houses using light‐gauge steel as a structural member have been developed and constructed since the early 2000s as a new construction pattern in the low‐rise construction market in Korea. Generally, the steel frames consist of two major load‐carrying elements such as load‐bearing wall and floor construction made up of approximately 1.0‐mm cold‐formed light‐gauge steel and light‐weight boards. Therefore, the steel frames are very simple to construct and make the construction period shorter than the ordinary construction type or concrete‐based construction. In Korea, regardless of the construction material types, the building regulation requires 1‐h fire rating for apartment buildings of four stories or under. To meet the fire resistance, new models of load‐bearing wall and floor should be developed. From the fire test results, two layer gypsum boards of 12.5 mm in thickness reinforced with glass fiber were proven satisfactory to provide 1‐h fire resistance with load‐bearing wall and floor. Copyright © 2012 John Wiley & Sons, Ltd.
Experimental study of the fire resistance of walls and floors constructed with steel studs and steel joists
Steel‐framed houses using light‐gauge steel as a structural member have been developed and constructed since the early 2000s as a new construction pattern in the low‐rise construction market in Korea. Generally, the steel frames consist of two major load‐carrying elements such as load‐bearing wall and floor construction made up of approximately 1.0‐mm cold‐formed light‐gauge steel and light‐weight boards. Therefore, the steel frames are very simple to construct and make the construction period shorter than the ordinary construction type or concrete‐based construction. In Korea, regardless of the construction material types, the building regulation requires 1‐h fire rating for apartment buildings of four stories or under. To meet the fire resistance, new models of load‐bearing wall and floor should be developed. From the fire test results, two layer gypsum boards of 12.5 mm in thickness reinforced with glass fiber were proven satisfactory to provide 1‐h fire resistance with load‐bearing wall and floor. Copyright © 2012 John Wiley & Sons, Ltd.
Experimental study of the fire resistance of walls and floors constructed with steel studs and steel joists
Kwon, In‐Kyu (Autor:in) / Jee, NamYong (Autor:in)
Fire and Materials ; 38 ; 77-91
01.01.2014
15 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
British Library Online Contents | 2014
|Pressed steel joists and studs
Engineering Index Backfile | 1923
|Thin slab concrete floors over steel joists