A platform for research: civil engineering, architecture and urbanism
Deck Slab Repaired by Fibrous Concrete Overlay
The concrete deck on the visitors' overlook facility at Libby Dam became badly cracked and in need of repair. It was decided to overlay the existing surface with 0.75-in. to 2-in. (18 mm to 50 mm) of fibrous concrete. Cracks in the original surface and some expansion joints were overlain without special treatment. Union workers with no special training used standard tools and techniques to successfully place the overlay. By magnesium floating the surface they obtained excellent /0.125-in. per 10-ft (3 mm per 3 m)/ grade control and produced a skid resistant surface with virtually all fibers covered. A mix design procedure based on workability was developed for this placement. The simple procedure is available from the U.S. Army Corps of Engineers, Walla Walla District, and is good for mixes from mortar to 0.75-in. (18 mm) aggregates. After a couple years of service an evaluation of the overlay shows 90% reduction in cracking, 100% reduction in water leakage through the surface, and essentially no rusting or evidence of fibers at the surface.
Deck Slab Repaired by Fibrous Concrete Overlay
The concrete deck on the visitors' overlook facility at Libby Dam became badly cracked and in need of repair. It was decided to overlay the existing surface with 0.75-in. to 2-in. (18 mm to 50 mm) of fibrous concrete. Cracks in the original surface and some expansion joints were overlain without special treatment. Union workers with no special training used standard tools and techniques to successfully place the overlay. By magnesium floating the surface they obtained excellent /0.125-in. per 10-ft (3 mm per 3 m)/ grade control and produced a skid resistant surface with virtually all fibers covered. A mix design procedure based on workability was developed for this placement. The simple procedure is available from the U.S. Army Corps of Engineers, Walla Walla District, and is good for mixes from mortar to 0.75-in. (18 mm) aggregates. After a couple years of service an evaluation of the overlay shows 90% reduction in cracking, 100% reduction in water leakage through the surface, and essentially no rusting or evidence of fibers at the surface.
Deck Slab Repaired by Fibrous Concrete Overlay
Schrader, Ernest K. (author) / Munch, Anthony V. (author)
Journal of the Construction Division ; 102 ; 179-196
2021-01-01
181976-01-01 pages
Article (Journal)
Electronic Resource
Unknown
Low-Cycle Fatigue Testing of High-Performance Concrete Bonded Overlay-Bridge Deck Slab Systems
British Library Online Contents | 2007
|Low-Cycle Fatigue Testing of High-Performance Concrete Bonded Overlay-Bridge Deck Slab Systems
Online Contents | 2007
|DECK COMPOSITE SLAB, AND CONCRETE THICKENING METHOD FOR DECK COMPOSITE SLAB
European Patent Office | 2023
|Conductive Concrete Overlay for Bridge Deck Deicing
British Library Online Contents | 1999
|