A platform for research: civil engineering, architecture and urbanism
Comparative Field Study of Cable Tension Measurement for a Cable-Stayed Bridge
Cable tension is one of the important indexes of cable integrity as well as bridge stability and can be measured by various tension measurement methods. In this study, three widely used methods (i.e., the lift-off test, electromagnetic sensor method, and vibration method) have been implemented for two multistrand cables of a cable-stayed bridge under construction. The test bridge is Hwamyung Bridge in Korea, which has a prestressed concrete box girder. The field tests are executed during the second tensioning stage just after the installation of the key segment. The tensions are estimated before and after tensioning the cable and 5 days later (i.e., after finishing the tensioning of all the cables). The tensions measured by the three methods are compared with the design tension of the tensioning stage, and all three methods show very good performance in accuracy with minimal difference. Their cost and difficulty are compared based on test experiences. Additionally, an improved vibration method is proposed by ignoring apparent negative bending stiffness identified from measurement errors and validated in this test by improving the accuracy.
Comparative Field Study of Cable Tension Measurement for a Cable-Stayed Bridge
Cable tension is one of the important indexes of cable integrity as well as bridge stability and can be measured by various tension measurement methods. In this study, three widely used methods (i.e., the lift-off test, electromagnetic sensor method, and vibration method) have been implemented for two multistrand cables of a cable-stayed bridge under construction. The test bridge is Hwamyung Bridge in Korea, which has a prestressed concrete box girder. The field tests are executed during the second tensioning stage just after the installation of the key segment. The tensions are estimated before and after tensioning the cable and 5 days later (i.e., after finishing the tensioning of all the cables). The tensions measured by the three methods are compared with the design tension of the tensioning stage, and all three methods show very good performance in accuracy with minimal difference. Their cost and difficulty are compared based on test experiences. Additionally, an improved vibration method is proposed by ignoring apparent negative bending stiffness identified from measurement errors and validated in this test by improving the accuracy.
Comparative Field Study of Cable Tension Measurement for a Cable-Stayed Bridge
Cho, Soojin (author) / Yim, Jinsuk (author) / Shin, Sung Woo (author) / Jung, Hyung-Jo (author) / Yun, Chung-Bang (author) / Wang, Ming L. (author)
Journal of Bridge Engineering ; 18 ; 748-757
2012-07-21
102013-01-01 pages
Article (Journal)
Electronic Resource
English
Comparative Field Study of Cable Tension Measurement for a Cable-Stayed Bridge
Online Contents | 2013
|Comparative Field Study of Cable Tension Measurement for a Cable-Stayed Bridge
Online Contents | 2013
Comparative Field Study of Cable Tension Measurement for a Cable-Stayed Bridge
British Library Online Contents | 2013
|Cable Tension Measurement of Cable Stayed Bridge Based on Frequency Method
British Library Conference Proceedings | 2013
|Cable-stayed bridge cable beam anchoring structure and cable-stayed bridge
European Patent Office | 2020
|