A platform for research: civil engineering, architecture and urbanism
Six half-scale models of reinforced concrete coupling beams with span/depth ratios ≤ 2.0 were tested under reversed cyclic load by a newly developed test method that can accurately simulate the boundary conditions of coupling beams in coupled shear wall structures. Five of them were conventionally reinforced and one was diagonally reinforced. Span/depth ratio and reinforcement layout were the main structural variables studied. Test results revealed that the deep conventionally reinforced coupling beams behaved quite differently from the ordinary beams in frame structures. Generally, shear failure was more likely to occur. Moreover, the additional longitudinal reinforcement bars (those placed near the centroidal axis) could contribute significantly to bending strength and therefore lead to an increase in shear demand. Nevertheless, the measured drift ratios of the conventionally reinforced coupling beams still reached 3·6-5·7%, which are not small for deep coupling beams. On the other hand, it was found that the provision of diagonal reinforcement radically changed the load resisting mechanism and significantly improved the energy dissipation capacity of the coupling beam. However, it had not improved the deformability of the coupling beam. ; published_or_final_version
Six half-scale models of reinforced concrete coupling beams with span/depth ratios ≤ 2.0 were tested under reversed cyclic load by a newly developed test method that can accurately simulate the boundary conditions of coupling beams in coupled shear wall structures. Five of them were conventionally reinforced and one was diagonally reinforced. Span/depth ratio and reinforcement layout were the main structural variables studied. Test results revealed that the deep conventionally reinforced coupling beams behaved quite differently from the ordinary beams in frame structures. Generally, shear failure was more likely to occur. Moreover, the additional longitudinal reinforcement bars (those placed near the centroidal axis) could contribute significantly to bending strength and therefore lead to an increase in shear demand. Nevertheless, the measured drift ratios of the conventionally reinforced coupling beams still reached 3·6-5·7%, which are not small for deep coupling beams. On the other hand, it was found that the provision of diagonal reinforcement radically changed the load resisting mechanism and significantly improved the energy dissipation capacity of the coupling beam. However, it had not improved the deformability of the coupling beam. ; published_or_final_version
Cyclic behaviour of deep reinforced concrete coupling beams
2002-01-01
152
Article (Journal)
Electronic Resource
English
DDC:
690
Cyclic Behavior of Retrofitted-Reinforced Concrete Coupling Beams
Springer Verlag | 2018
|Plate-strengthened deep reinforced concrete coupling beams
Online Contents | 2011
|Nonlinear behavior of deep reinforced concrete coupling beams
British Library Online Contents | 2003
|Strength and behaviour of deep reinforced concrete beams
Engineering Index Backfile | 1967
|