A platform for research: civil engineering, architecture and urbanism
Fire Department Response Model (FDRM) and Fire Department Effectiveness Model (FDEM) theory report
As Canada and other countries move from prescriptive-based building codes to performance/objective-based codes, new design tools are needed to demonstrate that compliance with these new codes has been achieved. One such tool is the computer model FiRECAM, which has been developed over the past decade by the Fire Risk Management Program of the Institute for Research in Construction at the National Research Council of Canada (NRC). FiRECAM is a computer model for evaluating fire protection systems in residential and office buildings that can be used to compare the relative expected safety and cost of candidate fire protection options.The purpose of this document is to describe two sub-models of FIERAsystem, namely, the Fire Department Response Model (FDRM) and the Fire Department Effectiveness Model (FDEM). These two sub-models, though can be used as stand-alone models, are strongly interconnected. The time of intervention of a fire department that is calculated by the FDRM is used in the calculations of the FDEM. ; Depuis que le Canada et de nombreux autres pays ont choisi d'élaborer des codes du bâtiment axés sur la performance et les objectifs et de délaisser leurs codes prescriptifs, il est apparu nécessaire de développer de nouveaux outils de conception pour garantir la conformité de ces nouveaux codes. FIRECAMMD est l'un de ces outils. Ce modèle informatisé a été mis au point au cours des dix dernières années par l'équipe du Programme de gestion des risques d'incendie de l'Institut de recherche en construction du Conseil national de recherches Canada (CNRC). FIRECAMMD est un outil d'évaluation des systèmes de sécurité-incendie des immeubles à bureaux et à appartements qui servent à comparer la sécurité recherchée relative et les coûts des options sécurité-incendie. Le rapport décrit les deux sous-modèles du FIERAsystem, le Modèle d'ntervention des services incendie (MISI) et le Modèle d'efficacité des services incendie (MESI). Ces deux sous-modèles peuvent être utilisés comme modèles à part entière, puisqu'ils sont fortement interconnectés. Le délai d'intervention des services d'incendie calculé par le MISI est utilisé dans les calculs du MESI. ; Peer reviewed: No ; NRC publication: Yes
Fire Department Response Model (FDRM) and Fire Department Effectiveness Model (FDEM) theory report
As Canada and other countries move from prescriptive-based building codes to performance/objective-based codes, new design tools are needed to demonstrate that compliance with these new codes has been achieved. One such tool is the computer model FiRECAM, which has been developed over the past decade by the Fire Risk Management Program of the Institute for Research in Construction at the National Research Council of Canada (NRC). FiRECAM is a computer model for evaluating fire protection systems in residential and office buildings that can be used to compare the relative expected safety and cost of candidate fire protection options.The purpose of this document is to describe two sub-models of FIERAsystem, namely, the Fire Department Response Model (FDRM) and the Fire Department Effectiveness Model (FDEM). These two sub-models, though can be used as stand-alone models, are strongly interconnected. The time of intervention of a fire department that is calculated by the FDRM is used in the calculations of the FDEM. ; Depuis que le Canada et de nombreux autres pays ont choisi d'élaborer des codes du bâtiment axés sur la performance et les objectifs et de délaisser leurs codes prescriptifs, il est apparu nécessaire de développer de nouveaux outils de conception pour garantir la conformité de ces nouveaux codes. FIRECAMMD est l'un de ces outils. Ce modèle informatisé a été mis au point au cours des dix dernières années par l'équipe du Programme de gestion des risques d'incendie de l'Institut de recherche en construction du Conseil national de recherches Canada (CNRC). FIRECAMMD est un outil d'évaluation des systèmes de sécurité-incendie des immeubles à bureaux et à appartements qui servent à comparer la sécurité recherchée relative et les coûts des options sécurité-incendie. Le rapport décrit les deux sous-modèles du FIERAsystem, le Modèle d'ntervention des services incendie (MISI) et le Modèle d'efficacité des services incendie (MESI). Ces deux sous-modèles peuvent être utilisés comme modèles à part entière, puisqu'ils sont fortement interconnectés. Le délai d'intervention des services d'incendie calculé par le MISI est utilisé dans les calculs du MESI. ; Peer reviewed: No ; NRC publication: Yes
Fire Department Response Model (FDRM) and Fire Department Effectiveness Model (FDEM) theory report
Bénichou, N. (author) / Kashef, A. (author) / Hadjisophocleous, G. V. (author)
2002-03-01
doi:10.4224/20378822
Paper
Electronic Resource
English
DDC:
690
Measuring Fire Department Effectiveness
British Library Online Contents | 1993
|Wiley | 2008
|Fire Department Emergency Response
NTIS | 1997
|Fire Department Extinguishment
Wiley | 2017
|British Library Conference Proceedings | 1999