ANALYSIS OF DIMENSIONAL AND CALCULATIONS STRUCTURE DESIGNED BASED ON SNI 2847-2013
Floor slabs are structural components of a building that have certain dimensions to transmit dead and live loads on them to be distributed to their supports. Designing the floor slabs of a building, load data will be borne by the structure, so that the planned structure is able to bear the loads and forces that work. With careful planning, it is expected that the dimensions and reinforcement of the floor slabs are economical and safe which can avoid deflection and cracks. The building being reviewed is hospitals in Surabaya. This building consists of 9 floors with a height of up to 37 m. Planning dimensions and reinforcement in this hospital building includes two-way slabs with different size variations. The analysis was carried out using the 'envelope method' in accordance with SNI 2847: 2013 (Basics of Reinforced Concrete Planning). The results of the analysis of dimensions and reinforcement in this hospital building are: a) the dimensions / thickness of the plate on the roof plate is 125 mm, while b) the reinforcement used on this floor plate is Ø10-125 and the reinforcement for Ø10-200. Each moment analyzed is contained in the analysis results table and floor slab reinforcement drawings.
ANALYSIS OF DIMENSIONAL AND CALCULATIONS STRUCTURE DESIGNED BASED ON SNI 2847-2013
Floor slabs are structural components of a building that have certain dimensions to transmit dead and live loads on them to be distributed to their supports. Designing the floor slabs of a building, load data will be borne by the structure, so that the planned structure is able to bear the loads and forces that work. With careful planning, it is expected that the dimensions and reinforcement of the floor slabs are economical and safe which can avoid deflection and cracks. The building being reviewed is hospitals in Surabaya. This building consists of 9 floors with a height of up to 37 m. Planning dimensions and reinforcement in this hospital building includes two-way slabs with different size variations. The analysis was carried out using the 'envelope method' in accordance with SNI 2847: 2013 (Basics of Reinforced Concrete Planning). The results of the analysis of dimensions and reinforcement in this hospital building are: a) the dimensions / thickness of the plate on the roof plate is 125 mm, while b) the reinforcement used on this floor plate is Ø10-125 and the reinforcement for Ø10-200. Each moment analyzed is contained in the analysis results table and floor slab reinforcement drawings.
ANALYSIS OF DIMENSIONAL AND CALCULATIONS STRUCTURE DESIGNED BASED ON SNI 2847-2013
Ramadhan, Rizki Alif (author) / Rahmawati, Anita (author) / Warsito, Warsito (author)
2021-06-24
doi:10.33474/jice.v2i1.11272
Jurnal Ilmiah Teknik Sipil - JITS; Vol 2, No 1 (2021); 43-50 ; Journal Innovation of Civil Engineering (JICE); Vol 2, No 1 (2021); 43-50 ; 27755592
Article (Journal)
Electronic Resource
English
DDC:
690
BASE | 2021
|Redesain Awana Condotel Menggunakan Metode Flat slab Berdasarkan SNI 2847-2013
DOAJ | 2020
|THE EVALUATION OF THE CAUSES OF RETAINING WALL STRUCTURE FAILURE AT A RIVER BASED ON SNI 2847:2013
BASE | 2020
|Perencanaan Struktur Gedung 5 Lantai Menggunakan Balok dan Pelat Prategang Sesuai SNI 2847 2013
BASE | 2018
|