Analysis of load capacity of roof trusses with imperfections and the issue of equivalent load adoption
The internal forces and stresses were analyzed and utilization of the design resistance in selected members of the roof structure with local and global geometrical imperfections was evaluated. Values of these imperfections were based on the information given in the standards EN 1090-2 and EN 1993-1-1. Besides the basic reference model with imperfections, models without imperfections, with different equivalent load arrangements by the authors’ own concept and comparatively according to the standard EN 1993-1-1 were analyzed. The calculations were made using the 1st and the 2nd order analysis. Conclusion concerning accuracy of the internal forces estimation and limit states check by use the equivalent load system proposed in the standard EN 1993-1-1 are presented. Deficiencies in the provisions of this standard in terms of adopting equivalent loads in roof structures with imperfections, resulting in underestimation of the stresses in the bottom chords of the roof trusses, has been demonstrated.
Analysis of load capacity of roof trusses with imperfections and the issue of equivalent load adoption
The internal forces and stresses were analyzed and utilization of the design resistance in selected members of the roof structure with local and global geometrical imperfections was evaluated. Values of these imperfections were based on the information given in the standards EN 1090-2 and EN 1993-1-1. Besides the basic reference model with imperfections, models without imperfections, with different equivalent load arrangements by the authors’ own concept and comparatively according to the standard EN 1993-1-1 were analyzed. The calculations were made using the 1st and the 2nd order analysis. Conclusion concerning accuracy of the internal forces estimation and limit states check by use the equivalent load system proposed in the standard EN 1993-1-1 are presented. Deficiencies in the provisions of this standard in terms of adopting equivalent loads in roof structures with imperfections, resulting in underestimation of the stresses in the bottom chords of the roof trusses, has been demonstrated.
Analysis of load capacity of roof trusses with imperfections and the issue of equivalent load adoption
Grzegorz Gremza (author) / Jan Zamorowski (author)
2021
Article (Journal)
Electronic Resource
Unknown
Metadata by DOAJ is licensed under CC BY-SA 1.0
Load-carrying capacity of space trusses under the influence of imperfections
British Library Conference Proceedings | 1993
|Behaviour and Load Carrying Capacity of Steel Trusses in Service with Imperfections
British Library Conference Proceedings | 1995
|Heavy snow load sustained by timber roof trusses
Engineering Index Backfile | 1932
|Statical behaviour and load bearing capacity of historical roof trusses in Swedish churches
British Library Conference Proceedings | 1995
|Ultimate load design for R. C. tension members i roof trusses