Thermal Performance and Optimizing of Composite Trombe Wall with Temperature-Controlled DC Fan in Winter
This paper discusses an improved approach to the Trombe wall: an insulated panel is installed on the inner side, and vents are installed at the top and bottom to connect the outer and inner air layer with the interior. Direct current (DC) fans are installed in the upper vents for stable control of the air circulation. The study first analyzed the thermal performance of this composite Trombe wall, for which the heat load was 27.3% less compared to the classic Trombe wall and 32.1% less compared to the case without the Trombe wall. However, its efficiency for heating the room temperature was not high without heating. Then, we optimized the ventilation efficiency, the proportion of the Trombe wall in the room, and the type of glazing. The highest heat load savings could be achieved when the ventilation openings used high ventilation with temperature-controlled fans and the Trombe wall about 3% of the house floor area. With the use of Low-e double-glazing, we were able to save nearly 41.3% of the heat load than that with the regular single-glazing. For the composite Trombe wall, after taking into account the optimization factors, the room temperature was significantly higher, and could save nearly 52.3% of energy compared to the pre-optimization period.
Thermal Performance and Optimizing of Composite Trombe Wall with Temperature-Controlled DC Fan in Winter
This paper discusses an improved approach to the Trombe wall: an insulated panel is installed on the inner side, and vents are installed at the top and bottom to connect the outer and inner air layer with the interior. Direct current (DC) fans are installed in the upper vents for stable control of the air circulation. The study first analyzed the thermal performance of this composite Trombe wall, for which the heat load was 27.3% less compared to the classic Trombe wall and 32.1% less compared to the case without the Trombe wall. However, its efficiency for heating the room temperature was not high without heating. Then, we optimized the ventilation efficiency, the proportion of the Trombe wall in the room, and the type of glazing. The highest heat load savings could be achieved when the ventilation openings used high ventilation with temperature-controlled fans and the Trombe wall about 3% of the house floor area. With the use of Low-e double-glazing, we were able to save nearly 41.3% of the heat load than that with the regular single-glazing. For the composite Trombe wall, after taking into account the optimization factors, the room temperature was significantly higher, and could save nearly 52.3% of energy compared to the pre-optimization period.
Thermal Performance and Optimizing of Composite Trombe Wall with Temperature-Controlled DC Fan in Winter
Yuewei Zhu (author) / Tao Zhang (author) / Qingsong Ma (author) / Hiroatsu Fukuda (author)
2022
Article (Journal)
Electronic Resource
Unknown
Metadata by DOAJ is licensed under CC BY-SA 1.0
Optimizing energy and environmental performance of passive Trombe wall
Online Contents | 2014
|Trombe Wall Retrofit. Final Performance Report
NTIS | 1979
|British Library Conference Proceedings | 1984
|Heat transfer performance of the Trombe wall implanted with heat pipes during daytime in winter
Taylor & Francis Verlag | 2019
|