A platform for research: civil engineering, architecture and urbanism
Estimates of flame size from burning timber stacks based on observations of timber yard fires; separation distance of timber yards of different sizes from neighboring buildings are recommended.
Spacing from timber stacks to reduce fire spread
Instn Fire Engrs Quarterly
Law, M. (author)
1963
4 pages
Article (Journal)
English
© Metadata Copyright Elsevier B. V. All rights reserved.
Spacing of split-ring timber connectors
Engineering Index Backfile | 1943
|Composite stacks reduce maintenance
British Library Online Contents | 2011
British Library Online Contents | 2005
|The effect of building morphology on fire spread in UK timber-floor high-rise
British Library Conference Proceedings | 2006
|