A platform for research: civil engineering, architecture and urbanism
Eisenhower and Grass River Locks have filling and emptying systems that utilize longitudinal culverts, side ports and tainter type valves; vertical lift gate provided at entrance to upstream lock to close off flow in event of failure of miter gates; pool between two locks is regulated by culverts placed in lock walls; development of hydraulic design criteria and selection of pool levels.
Eisenhower and Grass River Locks have filling and emptying systems that utilize longitudinal culverts, side ports and tainter type valves; vertical lift gate provided at entrance to upstream lock to close off flow in event of failure of miter gates; pool between two locks is regulated by culverts placed in lock walls; development of hydraulic design criteria and selection of pool levels.
American locks of St. Lawrence Seaway
ASCE -- Proc (J Waterways Harbors Div)
Davis, J.P. (author)
1958
16 pages
Article (Journal)
English
© Metadata Copyright Elsevier B. V. All rights reserved.
Investigation of concrete in Eisenhower and Snell Locks st. Lawrence seaway
Engineering Index Backfile | 1967
Engineering Index Backfile | 1958
|Engineering Index Backfile | 1957