A platform for research: civil engineering, architecture and urbanism
Tacoma narrows bridge failure
Committee concluded that failure of this bridge shows that methods of design computations, which had proven satisfactory on structures of other proportions, were not satisfactory for designing structure of proportions used in Tacoma Narrows Bridge; methods used in attempting to reduce oscillations which were found to occur after completion of bridge, were not affective, although they perhaps delayed destruction of bridge.
Tacoma narrows bridge failure
Committee concluded that failure of this bridge shows that methods of design computations, which had proven satisfactory on structures of other proportions, were not satisfactory for designing structure of proportions used in Tacoma Narrows Bridge; methods used in attempting to reduce oscillations which were found to occur after completion of bridge, were not affective, although they perhaps delayed destruction of bridge.
Tacoma narrows bridge failure
Am Soc Civ Engrs -- Report
1942
18 pages
26-p Appendix
Report
English
© Metadata Copyright Elsevier B. V. All rights reserved.
Failure of Tacoma narrows bridge
Engineering Index Backfile | 1944
Failure of Tacoma narrows bridge
Engineering Index Backfile | 1943
Failure of Tacoma narrows bridge
Engineering Index Backfile | 1941
|Failure of Tacoma narrows bridge
Engineering Index Backfile | 1941
Engineering Index Backfile | 1940
|