A platform for research: civil engineering, architecture and urbanism
Rigid frame span building in Durban
Illustrated description of all welded steel structure for industrial plant in Durban, South Africa; span of frames is 117 ft; 130 ft 1 in. between gable walls is divided into 10 bays spanned by 6×3-in. timber purlins; stress analysis was performed by model analysis method; cost of welded structure was 3s 10d per sq ft against 4s per sq ft of riveted structure; 6.3 lb of steel consumed per sq ft.
Rigid frame span building in Durban
Illustrated description of all welded steel structure for industrial plant in Durban, South Africa; span of frames is 117 ft; 130 ft 1 in. between gable walls is divided into 10 bays spanned by 6×3-in. timber purlins; stress analysis was performed by model analysis method; cost of welded structure was 3s 10d per sq ft against 4s per sq ft of riveted structure; 6.3 lb of steel consumed per sq ft.
Rigid frame span building in Durban
Civ Engrs Rev
Zakrzewski, M.S. (author)
1950
6 pages
Article (Journal)
English
© Metadata Copyright Elsevier B. V. All rights reserved.
Rigid frame 87 ft. 6 in. Span building in Durban
Engineering Index Backfile | 1950
|Unique three-span rigid-frame bridge
Engineering Index Backfile | 1932
|Rigid-frame concrete span requires no falsework
Engineering Index Backfile | 1945
|