Effect of loads on culverts
Experiments on 24- to 48-in. pipe culverts under actual embankments up to 38 ft. height, with measurements of pressures at various parts of circumference; deflection of flexible pipe produces uniform pressures at all points.
Effect of loads on culverts
Experiments on 24- to 48-in. pipe culverts under actual embankments up to 38 ft. height, with measurements of pressures at various parts of circumference; deflection of flexible pipe produces uniform pressures at all points.
Effect of loads on culverts
Pub. Works
Public Works ; 57
1926
4 pages
2 Figs.
Article (Journal)
English
© Metadata Copyright Elsevier B. V. All rights reserved.
Design Live Loads on Box Culverts
NTIS | 2002
|Loads on Box Culverts Under High Embankments
NTIS | 1974
|Three-Dimensional Modeling of Live Loads on Culverts
ASCE | 2006
|Engineering Index Backfile | 1939