A platform for research: civil engineering, architecture and urbanism
Indoor environment and passengers’ comfort in subway stations in Seoul
Abstract The purpose of this study is to investigate the indoor environment of subway stations and passengers’ comfort in three seasons. Six subway stations in Seoul were selected for physical environment measurements and a survey of 5282 passengers; these two components were conducted together. The questionnaire addressed thermal, air, light, acoustic and overall comfort. Seoul subway stations had large differences in air temperature in some seasons, and the air temperature in winter was very low. The concentration of particulate matter (PM) and carbon dioxide satisfied the indoor air quality maintenance criteria. Most survey respondents felt ‘neutral’ about or ‘comfortable’ with the environment in the subway stations, even in very low temperatures. From the results of the correlation analysis between the SET* and the percentage of uncomfortable passengers, the comfort range was 16.1–31.2 SET*°C for the concourses and 15.9–31.5 SET*°C for the platforms, which was a wider range than previous studies from other countries.
Highlights The air temperature in winter was very low in Seoul subway stations. The air environment in Seoul subway stations followed the maintenance criteria. The passengers’ comfort evaluation in subway stations was a considerably generous. The thermal comfort range was a wider range than that of other countries. Comfort range was 16.1–31.2 SET*°C for the concourses and 15.9–31.5 SET*°C for the platforms.
Indoor environment and passengers’ comfort in subway stations in Seoul
Abstract The purpose of this study is to investigate the indoor environment of subway stations and passengers’ comfort in three seasons. Six subway stations in Seoul were selected for physical environment measurements and a survey of 5282 passengers; these two components were conducted together. The questionnaire addressed thermal, air, light, acoustic and overall comfort. Seoul subway stations had large differences in air temperature in some seasons, and the air temperature in winter was very low. The concentration of particulate matter (PM) and carbon dioxide satisfied the indoor air quality maintenance criteria. Most survey respondents felt ‘neutral’ about or ‘comfortable’ with the environment in the subway stations, even in very low temperatures. From the results of the correlation analysis between the SET* and the percentage of uncomfortable passengers, the comfort range was 16.1–31.2 SET*°C for the concourses and 15.9–31.5 SET*°C for the platforms, which was a wider range than previous studies from other countries.
Highlights The air temperature in winter was very low in Seoul subway stations. The air environment in Seoul subway stations followed the maintenance criteria. The passengers’ comfort evaluation in subway stations was a considerably generous. The thermal comfort range was a wider range than that of other countries. Comfort range was 16.1–31.2 SET*°C for the concourses and 15.9–31.5 SET*°C for the platforms.
Indoor environment and passengers’ comfort in subway stations in Seoul
Han, Jieun (author) / Kwon, Soon-bark (author) / Chun, Chungyoon (author)
Building and Environment ; 104 ; 221-231
2016-05-03
11 pages
Article (Journal)
Electronic Resource
English
Indoor environment and passengers’ comfort in subway stations in Seoul
Online Contents | 2016
|Indoor environment and passengers’ comfort in subway stations in Seoul
British Library Online Contents | 2016
|Spatial Differentiation in Seoul Subway Transfer Stations
British Library Conference Proceedings | 2007
|Transient thermal comfort modeling in subway stations
British Library Conference Proceedings | 2009
|