Sonothrombolysis - Dissolving Thrombi by Interaction of the Drug and Ultrasound
Under the influence of pathological changes, the blood coagulates inside the blood vessel, creating a thrombus. The thrombus dissolution process is called thrombolysis. The aim of the study is to evaluate the thrombolysis process by the interaction of the thrombolitic drug and ultrasound. The clot dissolution process was analyzed in a specially designed, transparent for ultrasound parallel plate flow chamber. Inside, a freshly coagulated human blood sample was exposed to ultrasound. A liquid containing the tissue plasminogen activator drug in a concentration of 10 μg/ml passed around the sample. The liquid flow was forced by a peristaltic pump. The source of ultrasound was a 1 MHz flat ultrasonic transducer with a 25 mm diameter. The transducer radiated a 1000 periods burst, repeated every 2500 periods and space averaged time averaged intensities of 0.2-1.6 W /cm2, The efficacy of thrombus dissolution was observed by means of a designed parallel plate flow chamber and the time of thrombus complete dissolution was measured. The best result for the 1 MHz frequency and space averaged time averaged intensity of 1.6 W/cm2 was recorded, where the thrombus was dissolved within 5.5 minutes.
Sonothrombolysis - Dissolving Thrombi by Interaction of the Drug and Ultrasound
Under the influence of pathological changes, the blood coagulates inside the blood vessel, creating a thrombus. The thrombus dissolution process is called thrombolysis. The aim of the study is to evaluate the thrombolysis process by the interaction of the thrombolitic drug and ultrasound. The clot dissolution process was analyzed in a specially designed, transparent for ultrasound parallel plate flow chamber. Inside, a freshly coagulated human blood sample was exposed to ultrasound. A liquid containing the tissue plasminogen activator drug in a concentration of 10 μg/ml passed around the sample. The liquid flow was forced by a peristaltic pump. The source of ultrasound was a 1 MHz flat ultrasonic transducer with a 25 mm diameter. The transducer radiated a 1000 periods burst, repeated every 2500 periods and space averaged time averaged intensities of 0.2-1.6 W /cm2, The efficacy of thrombus dissolution was observed by means of a designed parallel plate flow chamber and the time of thrombus complete dissolution was measured. The best result for the 1 MHz frequency and space averaged time averaged intensity of 1.6 W/cm2 was recorded, where the thrombus was dissolved within 5.5 minutes.
Sonothrombolysis - Dissolving Thrombi by Interaction of the Drug and Ultrasound
Secomski, Wojciech (author) / Klimonda, Ziemowit (author) / Majka, Katarzyna (author) / Olszewski, Robert (author) / Nowicki, Andrzej (author)
2018-09-01
5124964 byte
Conference paper
Electronic Resource
English
Interventional Microbubble Enhanced Sonothrombolysis on Left Ventricular Assist Devices
Wiley | 2022
|Rapidly dissolving fibroin microneedles for transdermal drug delivery
British Library Online Contents | 2011
|Platelet Mimetic Particles for Targeting Thrombi in Flowing Blood
British Library Online Contents | 2012
|Dissolving Community Redevelopment
British Library Online Contents | 2011
|