Structural testing of corrugated asbestos-cement roof panels at the Hanford Facilities, Richland, Washington
This report describes a roof testing program that was carried out at the 105KE/KW Spent Fuel Storage Basins and their surrounding facilities at the Hanford Site in Richland, Washington. The roof panels were constructed in the mid 1950's of corrugated asbestos-cement (A/C), which showed common signs of aging. Based on the construction specifications, the panels capacity to meet current design standards was questioned. Both laboratory and in-situ load testing of the corrugated A/C panels was conducted. The objective of the complete test program was to determine the structural integrity of the existing A/C roof panels installed in the 105KE and 105KW facilities. The data from these tests indicated that the roofs are capable of resisting the design loads and are considered safe. A second phase test to address the roof resistance to personnel and roof removal/roofing system installation equipment was recommended and is underway.
Structural testing of corrugated asbestos-cement roof panels at the Hanford Facilities, Richland, Washington
This report describes a roof testing program that was carried out at the 105KE/KW Spent Fuel Storage Basins and their surrounding facilities at the Hanford Site in Richland, Washington. The roof panels were constructed in the mid 1950's of corrugated asbestos-cement (A/C), which showed common signs of aging. Based on the construction specifications, the panels capacity to meet current design standards was questioned. Both laboratory and in-situ load testing of the corrugated A/C panels was conducted. The objective of the complete test program was to determine the structural integrity of the existing A/C roof panels installed in the 105KE and 105KW facilities. The data from these tests indicated that the roofs are capable of resisting the design loads and are considered safe. A second phase test to address the roof resistance to personnel and roof removal/roofing system installation equipment was recommended and is underway.
Structural testing of corrugated asbestos-cement roof panels at the Hanford Facilities, Richland, Washington
S. E. Moustafa (author) / S. M. Rodehaver (author) / W. A. Frier (author)
1993
10 pages
Report
No indication
English
Asbestos-cement tubes in roof construction
Engineering Index Backfile | 1941
Concrete roof tile and cement asbestos shingles
Engineering Index Backfile | 1920
Eternit introduces improvements in asbestos cement corrugated sheets
Engineering Index Backfile | 1927