A platform for research: civil engineering, architecture and urbanism
This paper gives a method of analysis for both single and double skin stressed skin panels, with either rigid or semi rigid connections, which is suitable for hand calculation using an electronic calculator. By means of numerical examples it is demonstrated that there is good agreement between the method of analysis presented and alternative methods of analysis formulated by other workers. (Copyright (c) TRADA 1979.)
This paper gives a method of analysis for both single and double skin stressed skin panels, with either rigid or semi rigid connections, which is suitable for hand calculation using an electronic calculator. By means of numerical examples it is demonstrated that there is good agreement between the method of analysis presented and alternative methods of analysis formulated by other workers. (Copyright (c) TRADA 1979.)
Analysis of Plywood Stressed Skin Panels with Rigid or Semi Rigid Connections
I. Smith (author)
1979
68 pages
Report
No indication
English
Rigid timber frames in Cleveland exposition building utilize stressed plywood
Engineering Index Backfile | 1936
|Multiple fully stressed designs of steel frame structures with semi-rigid connections
Tema Archive | 2003
|Stressed skin structures in plywood
Engineering Index Backfile | 1942
|Semi-Rigid Structural Connections
Online Contents | 1996
Semi-rigid connections handbook
TIBKAT | 2011
|