A platform for research: civil engineering, architecture and urbanism
Seismic Stress Analysis of LOFT Room B-100 Cable Tray Supports
Cable tray supports in Room B-100 of TAN 630 have been analyzed for seismic loading. Results indicate the supports were designed for vertical loads only and are not adequate for the horizontal g-loading of a LOFT Safe Shutdown Earthquake (SSE). Either braces or structure modifications are necessary on nearly all the cable tray supports in this room. 3 refs., 4 figs. (ERA citation 10:044344)
Seismic Stress Analysis of LOFT Room B-100 Cable Tray Supports
Cable tray supports in Room B-100 of TAN 630 have been analyzed for seismic loading. Results indicate the supports were designed for vertical loads only and are not adequate for the horizontal g-loading of a LOFT Safe Shutdown Earthquake (SSE). Either braces or structure modifications are necessary on nearly all the cable tray supports in this room. 3 refs., 4 figs. (ERA citation 10:044344)
Seismic Stress Analysis of LOFT Room B-100 Cable Tray Supports
R. G. Rahl (author)
1979
16 pages
Report
No indication
English