A platform for research: civil engineering, architecture and urbanism
Effects of Thermal Shrinkage on Built-Up Roofing
The effects of thermal movement of bituminous built-up roof membranes are related to some common failures of built-up roofing observed in field exposures. A procedure for determining the amount of thermal movement of built-up membranes is described. Data are given for the thermal movement of various bitumens and reinforcing felts used in the construction of built-up roofs and for the composite membranes over a temperature range construction of built-up roofs and for the composite membranes over a temperature range of +30 to -30F. The data obtained are related to field experience and suggestions are presented which will prove beneficial in reducing the incidence of built-up failure due to thermal movement. (Author)
Effects of Thermal Shrinkage on Built-Up Roofing
The effects of thermal movement of bituminous built-up roof membranes are related to some common failures of built-up roofing observed in field exposures. A procedure for determining the amount of thermal movement of built-up membranes is described. Data are given for the thermal movement of various bitumens and reinforcing felts used in the construction of built-up roofs and for the composite membranes over a temperature range construction of built-up roofs and for the composite membranes over a temperature range of +30 to -30F. The data obtained are related to field experience and suggestions are presented which will prove beneficial in reducing the incidence of built-up failure due to thermal movement. (Author)
Effects of Thermal Shrinkage on Built-Up Roofing
W. C. Cullen (author)
1965
10 pages
Report
No indication
English
Construction Equipment, Materials, & Supplies , Civil Engineering , Roofs , Bituminous coatings , Construction materials , Thermal stresses , Membranes , Shrinkage , Failure(Mechanics) , Exposure , Cracks , Asphalt , Coal tar , Loading(Mechanics) , Moisture , Adhesives , Strain(Mechanics) , Construction , Roofing
Effects of thermal shrinkage on built-up roofing
Engineering Index Backfile | 1965
|NTIS | 1961
|Built-up roofing tension splits
Engineering Index Backfile | 1964
|Factors in estimating built-up roofing
Engineering Index Backfile | 1952
|Premature failure of built-up roofing
Engineering Index Backfile | 1963
|