A platform for research: civil engineering, architecture and urbanism
Permeability of cracked concrete
Abstract The goal of the research presented here was to study the relationship between cracking and water permeability. A feedback-controlled test was used to generate width-controlled cracks. Water permeability was evaluated by a low-pressure water permeability test. The factors chosen for the experimental design were material type (paste, mortar, normal and high strength concrete), thickness of the sample and average width of the induced cracks (ranging from 50 to 350 micrometers). The water permeability test results indicated that the relationships between permeability and material type differ for uncracked and cracked material, and that there was little thickness effect. Permeability of uncracked material decreased from paste, mortar, normal strength concrete (NSC) to high strength concrete (HSC). Water permeability of cracked material significantly increased with increasing crack width. For cracks above 100 microns, NSC showed the highest permeability coefficient, where as mortar showed the lowest one.
Permeability of cracked concrete
Abstract The goal of the research presented here was to study the relationship between cracking and water permeability. A feedback-controlled test was used to generate width-controlled cracks. Water permeability was evaluated by a low-pressure water permeability test. The factors chosen for the experimental design were material type (paste, mortar, normal and high strength concrete), thickness of the sample and average width of the induced cracks (ranging from 50 to 350 micrometers). The water permeability test results indicated that the relationships between permeability and material type differ for uncracked and cracked material, and that there was little thickness effect. Permeability of uncracked material decreased from paste, mortar, normal strength concrete (NSC) to high strength concrete (HSC). Water permeability of cracked material significantly increased with increasing crack width. For cracks above 100 microns, NSC showed the highest permeability coefficient, where as mortar showed the lowest one.
Permeability of cracked concrete
Aldea, C. -M. (author) / Shah, S. P. (author) / Karr, A. (author)
1999
Article (Journal)
English
Permeability, of cracked concrete
British Library Online Contents | 1999
|Permeability of cracked concrete
Springer Verlag | 1999
|Permeability Study of Cracked Concrete
Online Contents | 1997
|Permeability study of cracked concrete
Tema Archive | 1997
|Permeability of cracked concrete specimens
TIBKAT | 1984