Accelerated strength and testing of concrete in Jordan
Abstract Accelerated strength testing using the boiling water procedure of ASTM C 684 was performed to evaluate this test method for use in the routine quality control of concrete made of local materials, and in the prediction of potential quality and strength of concrete at later ages. 190 groups of standard concrete specimens were sampled: in each group two cylinders represented the accelerated strength and were tested at 28.5 h, while the other two were normally cured and tested at 28 days. Test results were recorded and statistically evaluated. A computer program was developed to carry out the numerical statistical computations and regression analysis. Correlations between the 28-day compressive strength and the corresponding accelerated strength were established, taking account of the utilization of local materials and practices. The outcome of this study confirms that accelerated strength testing can do everything the 28-day test can do but 27 days sooner. The conclusions derived provide experimental evidence in favour of implementing the standard boiling water method for use in relation to quality control and prediction of concrete strength at later ages.
Resume On a exécuté des essais accélérés par la méthode ASTM C 684 de l'eau bouillante (Boiling Water Procedure) pour évaluer les possibilités d'utilisation de cette méthode dans le contrôle de routine de la qualité du béton à base de matériaux locaux, et la prédiction de la qualité potentielle et de la résistance du béton aux âges plus avancés. On a essayé 190 séries d'échantillons de béton standard; dans chaque série, deux cylindres ont été essayés pendant 28,5 h pour l'accélération du durcissement, tandis que les deux autres étaient normalement conservés et essayés à 28 jours. On a enregistré, discuté et évalué statistiquement les résultats des essais. On a mis en place un programme informatique pour effectuer les calculs statistiques et le calcul de régression. On a établi des corrélations entre la résistance en compression à 28 jours et l'accélération du durcissement correspondante, compte tenu des pratiques et des matériaux locaux. A l'issue de cette étude, il se confirme que tout ce qui peut être réalisé avec des essais à 28 jours peut l'être 27 jours plus tôt grâce à l'accélération du durcissement. Les conclusions qu'on en tire sont expérimentalement en faveur de la méthode normalisée de l'eau bouillante pour le contrôle de qualité et la prédiction de la résistance du béton aux âges avancés.
Accelerated strength and testing of concrete in Jordan
Abstract Accelerated strength testing using the boiling water procedure of ASTM C 684 was performed to evaluate this test method for use in the routine quality control of concrete made of local materials, and in the prediction of potential quality and strength of concrete at later ages. 190 groups of standard concrete specimens were sampled: in each group two cylinders represented the accelerated strength and were tested at 28.5 h, while the other two were normally cured and tested at 28 days. Test results were recorded and statistically evaluated. A computer program was developed to carry out the numerical statistical computations and regression analysis. Correlations between the 28-day compressive strength and the corresponding accelerated strength were established, taking account of the utilization of local materials and practices. The outcome of this study confirms that accelerated strength testing can do everything the 28-day test can do but 27 days sooner. The conclusions derived provide experimental evidence in favour of implementing the standard boiling water method for use in relation to quality control and prediction of concrete strength at later ages.
Resume On a exécuté des essais accélérés par la méthode ASTM C 684 de l'eau bouillante (Boiling Water Procedure) pour évaluer les possibilités d'utilisation de cette méthode dans le contrôle de routine de la qualité du béton à base de matériaux locaux, et la prédiction de la qualité potentielle et de la résistance du béton aux âges plus avancés. On a essayé 190 séries d'échantillons de béton standard; dans chaque série, deux cylindres ont été essayés pendant 28,5 h pour l'accélération du durcissement, tandis que les deux autres étaient normalement conservés et essayés à 28 jours. On a enregistré, discuté et évalué statistiquement les résultats des essais. On a mis en place un programme informatique pour effectuer les calculs statistiques et le calcul de régression. On a établi des corrélations entre la résistance en compression à 28 jours et l'accélération du durcissement correspondante, compte tenu des pratiques et des matériaux locaux. A l'issue de cette étude, il se confirme que tout ce qui peut être réalisé avec des essais à 28 jours peut l'être 27 jours plus tôt grâce à l'accélération du durcissement. Les conclusions qu'on en tire sont expérimentalement en faveur de la méthode normalisée de l'eau bouillante pour le contrôle de qualité et la prédiction de la résistance du béton aux âges avancés.
Accelerated strength and testing of concrete in Jordan
Resheidat, M. R. (author) / Madanat, O. N. (author)
Materials and Structures ; 25 ; 79-83
1992-03-01
5 pages
Article (Journal)
Electronic Resource
English
Accelerated strength and testing of concrete in Jordan
Online Contents | 1992
|Concrete Q & A - Accelerated Concrete Strength Testing
Online Contents | 2012
Accelerated strength testing of concrete using boiling method
Engineering Index Backfile | 1966
|