Effects of Water Quality Parameters on the Corrosion of Galvanized Steel
Jar tests and a circulating water system were used to evaluate the effect of water quality parameters, in particular the Langelier index (SI), on the corrosion of galvanized steel. Since waters with a positive SI were sometimes found to be at least as corrosive as waters with a negative SI, especially if the effect of dissolved oxygen was neglected, no definite relationship could be established between corrosion rate and SI. In both Gainesville, Fla., tap water and deionized water, corrosion was observed to be fastest in the pH range 5–6.5. A general mechanism for the formation of corrosion products is presented. Overall results suggest that the SI should be used only with caution in the practice of corrosion control and that prediction of a water's corrosivity should also consider the influence of other water quality parameters.
Effects of Water Quality Parameters on the Corrosion of Galvanized Steel
Jar tests and a circulating water system were used to evaluate the effect of water quality parameters, in particular the Langelier index (SI), on the corrosion of galvanized steel. Since waters with a positive SI were sometimes found to be at least as corrosive as waters with a negative SI, especially if the effect of dissolved oxygen was neglected, no definite relationship could be established between corrosion rate and SI. In both Gainesville, Fla., tap water and deionized water, corrosion was observed to be fastest in the pH range 5–6.5. A general mechanism for the formation of corrosion products is presented. Overall results suggest that the SI should be used only with caution in the practice of corrosion control and that prediction of a water's corrosivity should also consider the influence of other water quality parameters.
Effects of Water Quality Parameters on the Corrosion of Galvanized Steel
Pisigan, Rodolfo A. Jr. (author) / Singley, J. Edward (author)
Journal ‐ American Water Works Association ; 77 ; 76-82
1985-11-01
7 pages
Article (Journal)
Electronic Resource
English
Alkalinity , Corrosivity , Steel Pipe , Hardness , Corrosion , pH , Water Quality
Diagnosis of Water Quality for Galvanized Steel Corrosion by Mahalanobis Distance
British Library Online Contents | 2008
|Diagnosis of Water Quality for Galvanized Steel Corrosion by Mahalanobis Distance
British Library Online Contents | 2008
|Corrosion of press-hardened galvanized steel
British Library Online Contents | 2012
|Effects of Deformation on Atmospheric Corrosion of Galvanized Steel
British Library Online Contents | 2006
|Corrosion of steel and galvanized steel in concrete
Engineering Index Backfile | 1966
|