A platform for research: civil engineering, architecture and urbanism
The seismic shear of ductile cantilever wall systems in multistorey structures
10.1002/eqe.384.abs
The distribution of seismic base shear demand among ductile flexural cantilever walls, comprising the lateral load resisting system of a multistorey building, is studied. It is shown that the base shear force demand depends on the sequence of hinge formation at the wall bases, and this in turn depends on the relative wall lengths. Hence, the routine elastic approach in which the shear forces are allocated per relative flexural rigidity or (when some consideration is given to plastic hinge formation) to moment capacity at the wall base, may appreciably underestimate the shear force demand on the walls, particularly the shorter (usually the more flexible) ones.
A simple procedure yielding the results of ‘cyclic’ pushover analysis is proposed to predict the peak seismic wall forces for a given total base shear when plastification is confined to the wall base. The effects of plastic hinges developing at higher floors on (1) shear distribution among the walls and (2) the in‐plane floor forces are also considered. Two numerical examples are presented to demonstrate the main points made. Copyright © 2004 John Wiley & Sons, Ltd.
The seismic shear of ductile cantilever wall systems in multistorey structures
10.1002/eqe.384.abs
The distribution of seismic base shear demand among ductile flexural cantilever walls, comprising the lateral load resisting system of a multistorey building, is studied. It is shown that the base shear force demand depends on the sequence of hinge formation at the wall bases, and this in turn depends on the relative wall lengths. Hence, the routine elastic approach in which the shear forces are allocated per relative flexural rigidity or (when some consideration is given to plastic hinge formation) to moment capacity at the wall base, may appreciably underestimate the shear force demand on the walls, particularly the shorter (usually the more flexible) ones.
A simple procedure yielding the results of ‘cyclic’ pushover analysis is proposed to predict the peak seismic wall forces for a given total base shear when plastification is confined to the wall base. The effects of plastic hinges developing at higher floors on (1) shear distribution among the walls and (2) the in‐plane floor forces are also considered. Two numerical examples are presented to demonstrate the main points made. Copyright © 2004 John Wiley & Sons, Ltd.
The seismic shear of ductile cantilever wall systems in multistorey structures
Rutenberg, Avigdor (author)
Earthquake Engineering & Structural Dynamics ; 33 ; 881-896
2004-06-01
16 pages
Article (Journal)
Electronic Resource
English
The seismic shear of ductile cantilever wall systems in multistorey structures
Online Contents | 2004
|Seismic behaviour of multistorey RC wall-frame system versus bare ductile frame system
Online Contents | 2002
|The Seismic Shear Demand in Ductile Cantilever Wall Systems and the EC8 Provisions
British Library Online Contents | 2006
|Seismic reliability functions for multistorey frame and wall-frame systems
Online Contents | 2006
|