A platform for research: civil engineering, architecture and urbanism
Preconcentration of Trace Arsenite and Arsenate with Titanium Dioxide Nanoparticles and Subsequent Determination by Silver Diethyldithiocarbamate Spectrophotometric Method
A novel method of preconcentration of trace arsenite and arsenate by using titanium dioxide nanoparticles as adsorbent was described. The concentrations of preconcentrated arsenite and arsenate were determined by a silver diethyldithiocarbamate spectrophotometric method without desorption. Batch adsorption experiments were carried out as a function of the pH, contact time, amount of titanium dioxide nanoparticles, and solution volume. In the pH range 5 to 6, adsorption rates of arsenite and arsenate were higher than 98%. The calibration coefficient was 0.9991, and the linear range was 0 to 100 μg/L. The developed method was precise, with the relative standard deviation <5% at concentration level of 10 μg/L, with a detection limit (3σ, n = 6) of 0.44 μg/L. The accuracy of the method for total arsenic was validated by standard reference materials (SRM 3103a) (National Institute of Standards and Technology, Gaithersburg, Maryland). The method was also applied to the analysis of arsenite and arsenate in natural water samples to verify the accuracy. The recovery values remained in a narrow range, from 95 to 103%.
Preconcentration of Trace Arsenite and Arsenate with Titanium Dioxide Nanoparticles and Subsequent Determination by Silver Diethyldithiocarbamate Spectrophotometric Method
A novel method of preconcentration of trace arsenite and arsenate by using titanium dioxide nanoparticles as adsorbent was described. The concentrations of preconcentrated arsenite and arsenate were determined by a silver diethyldithiocarbamate spectrophotometric method without desorption. Batch adsorption experiments were carried out as a function of the pH, contact time, amount of titanium dioxide nanoparticles, and solution volume. In the pH range 5 to 6, adsorption rates of arsenite and arsenate were higher than 98%. The calibration coefficient was 0.9991, and the linear range was 0 to 100 μg/L. The developed method was precise, with the relative standard deviation <5% at concentration level of 10 μg/L, with a detection limit (3σ, n = 6) of 0.44 μg/L. The accuracy of the method for total arsenic was validated by standard reference materials (SRM 3103a) (National Institute of Standards and Technology, Gaithersburg, Maryland). The method was also applied to the analysis of arsenite and arsenate in natural water samples to verify the accuracy. The recovery values remained in a narrow range, from 95 to 103%.
Preconcentration of Trace Arsenite and Arsenate with Titanium Dioxide Nanoparticles and Subsequent Determination by Silver Diethyldithiocarbamate Spectrophotometric Method
Xiao, Yabing (author) / Ling, Jie (author) / Qian, Shahua (author) / Lin, Anqing (author) / Zheng, Wenjie (author) / Xu, Weiya (author) / Luo, Yuxuan (author) / Zhang, Man (author)
Water Environment Research ; 79 ; 1015-1022
2007-09-01
8 pages
Article (Journal)
Electronic Resource
English
Influence of titanium dioxide nanoparticles on speciation and bioavailability of arsenite
Online Contents | 2009
|British Library Conference Proceedings | 2011
|British Library Online Contents | 1999
|