A platform for research: civil engineering, architecture and urbanism
Prefabricated Wood Truss Roof Failure under Wind Induced Loads
This paper presents a study to evaluate the performance of single-story multi-family buildings' truss roof structures subjected to tornadic wind loads. This study was conducted to determine whether the roof structures of a condominium complex located in Florida were damaged by the storm event that occurred at the site. The investigation consisted of an assessment of the storm wind speeds and a detailed structural engineering analysis. The roof framing consisted of prefabricated long span wood trusses with metal gusset plate connections, supported on exterior masonry block walls and anchored to tie beams with hurricane straps. A challenge for this investigation was to determine wind loads generated by tornadic winds which are different in magnitude compared to wind loads produced by straight line winds for the same wind speed. This paper describes in detail the analysis performed which revealed that the primary mode of failure was at the truss connector plates caused by wind uplift forces. The failure pattern obtained from the analysis was consistent with the damage assessment noted from on-site observations which indicated that the majority of failures occurred at truss plates along the truss top chords.
Prefabricated Wood Truss Roof Failure under Wind Induced Loads
This paper presents a study to evaluate the performance of single-story multi-family buildings' truss roof structures subjected to tornadic wind loads. This study was conducted to determine whether the roof structures of a condominium complex located in Florida were damaged by the storm event that occurred at the site. The investigation consisted of an assessment of the storm wind speeds and a detailed structural engineering analysis. The roof framing consisted of prefabricated long span wood trusses with metal gusset plate connections, supported on exterior masonry block walls and anchored to tie beams with hurricane straps. A challenge for this investigation was to determine wind loads generated by tornadic winds which are different in magnitude compared to wind loads produced by straight line winds for the same wind speed. This paper describes in detail the analysis performed which revealed that the primary mode of failure was at the truss connector plates caused by wind uplift forces. The failure pattern obtained from the analysis was consistent with the damage assessment noted from on-site observations which indicated that the majority of failures occurred at truss plates along the truss top chords.
Prefabricated Wood Truss Roof Failure under Wind Induced Loads
Arya, Behnam (author) / Jain, Anurag (author)
Sixth Congress on Forensic Engineering ; 2012 ; San Francisco, California, United States
Forensic Engineering 2012 ; 1228-1237
2012-11-13
Conference paper
Electronic Resource
English
Truss connecting structure of prefabricated building roof
European Patent Office | 2020
|Heightening installation method for prefabricated steel roof truss
European Patent Office | 2024
|WATER STORAGE TANK WITH prefabricated module CONICAL ROOF TRUSS
European Patent Office | 2020
|