Design studies for chute-des-passes surge-tank system
Downstream surge chamber for hydroelectric plant is provided in form of large draft-tube manifold running parallel to powerhouse; design of upstream tank required provision for plant to operate as isolated power source subject to large, instantaneous load increases; description of design studies, aided by electronic analog computer, that led to adoption of restricted orifice type upstream surge tank with unusually large diam of 130 ft.
Design studies for chute-des-passes surge-tank system
Downstream surge chamber for hydroelectric plant is provided in form of large draft-tube manifold running parallel to powerhouse; design of upstream tank required provision for plant to operate as isolated power source subject to large, instantaneous load increases; description of design studies, aided by electronic analog computer, that led to adoption of restricted orifice type upstream surge tank with unusually large diam of 130 ft.
Design studies for chute-des-passes surge-tank system
ASCE -- Proc (J Power Div)
Forster, J.W. (author)
1962
32 pages
Article (Journal)
English
© Metadata Copyright Elsevier B. V. All rights reserved.
Engineering Index Backfile | 1959
Chute-des-passes: construction drama
Engineering Index Backfile | 1957
|Chute-des-Passes gigantic construction project
Engineering Index Backfile | 1959
|Huge power project at Chute-des-Passes
Engineering Index Backfile | 1958
|Planning and construction of chute-des passes hydroelectric power project
Engineering Index Backfile | 1960
|