A platform for research: civil engineering, architecture and urbanism
Particulate admixture for enhanced freeze-thaw resistance of concrete
AbstractIncorporation of porous particles with at least 30 per cent total porosity and pore diameters, mainly between 0.3 and 2 microns, added to the plastic mix were found to improve significantly the freeze-thaw resistance of hydrated neat cement paste and concrete. Particles of commercially fired clay bricks, diatomaceous earth, and fly ash (sintered and agglomerated) were tested. The concentration required for the achievement of a given level of frost resistance depends on the physical characteristics of the material. Typically, granules of a particular brick (0.5 ± 0.08 mm in size, 36 per cent total porosity) in 16 wt per cent concentration allowed 0.5 w/c cement paste specimen to endure 1260 freeze-thaw cycles without injury. Incorporation of porous particles as admixtures eliminates the problems due to the instability and strength reducing effect of conventionally entrained air bubbles.
RésuméOn a trouvé que des particules poreuses incorporées à au moins 30% de porosité totale et de diamètres des pores, surtout entre 0.3 et 2 microns ajoutés au mélange plastique, améliorent significativement la résistance au gel et au dégel des pâtes de ciment et de béton purs hydratés. Les particules des briques d'argile cuites commercialement, la terre à diatomacées, et la cendre volante (calcinée et agglomérée) ont été mises à l'essai. La concentration nécessaire pour la réalisation d'un niveau donné de résistance au gel dépend des caractéristiques physiques du matériau. D'une manière typique, les granules d'un brique particulière (0.5 ± 0.08 mm de grosseur, porosité totale) de 36% d'une concentration du poids de 16% a permis a un spécimen de pâte de ciment ayant un teneur en eau de 0.5 d'endurer 1260 cycles de gel et de dégel sans avarie. En incorporant les particules poreuses en tant qu'adjuvants on élimine les problèmes causés par l'instabilité et l'effet de réduction de résistance des bulles d'air entrainées d'une manière conventionnelle.
Particulate admixture for enhanced freeze-thaw resistance of concrete
AbstractIncorporation of porous particles with at least 30 per cent total porosity and pore diameters, mainly between 0.3 and 2 microns, added to the plastic mix were found to improve significantly the freeze-thaw resistance of hydrated neat cement paste and concrete. Particles of commercially fired clay bricks, diatomaceous earth, and fly ash (sintered and agglomerated) were tested. The concentration required for the achievement of a given level of frost resistance depends on the physical characteristics of the material. Typically, granules of a particular brick (0.5 ± 0.08 mm in size, 36 per cent total porosity) in 16 wt per cent concentration allowed 0.5 w/c cement paste specimen to endure 1260 freeze-thaw cycles without injury. Incorporation of porous particles as admixtures eliminates the problems due to the instability and strength reducing effect of conventionally entrained air bubbles.
RésuméOn a trouvé que des particules poreuses incorporées à au moins 30% de porosité totale et de diamètres des pores, surtout entre 0.3 et 2 microns ajoutés au mélange plastique, améliorent significativement la résistance au gel et au dégel des pâtes de ciment et de béton purs hydratés. Les particules des briques d'argile cuites commercialement, la terre à diatomacées, et la cendre volante (calcinée et agglomérée) ont été mises à l'essai. La concentration nécessaire pour la réalisation d'un niveau donné de résistance au gel dépend des caractéristiques physiques du matériau. D'une manière typique, les granules d'un brique particulière (0.5 ± 0.08 mm de grosseur, porosité totale) de 36% d'une concentration du poids de 16% a permis a un spécimen de pâte de ciment ayant un teneur en eau de 0.5 d'endurer 1260 cycles de gel et de dégel sans avarie. En incorporant les particules poreuses en tant qu'adjuvants on élimine les problèmes causés par l'instabilité et l'effet de réduction de résistance des bulles d'air entrainées d'une manière conventionnelle.
Particulate admixture for enhanced freeze-thaw resistance of concrete
Litvan, G.G. (author) / Sereda, P.J. (author)
Cement and Concrete Research ; 8 ; 53-60
1977-10-11
8 pages
Article (Journal)
Electronic Resource
English
Freeze-thaw-resistant concrete admixture and freeze-thaw-resistant concrete using same
European Patent Office | 2021
|Development of concrete admixture to improve freeze-thaw durability
Engineering Index Backfile | 1964
|A New Efficient and Safe Admixture for Freeze/Thaw Resistant Concrete
Springer Verlag | 2017
|Trans Tech Publications | 2014
|British Library Conference Proceedings | 2014
|