Posey Canyon Arch Culvert Instrumentation
The report discusses the instrumentation of an 8-foot diameter reinforced concrete arch culvert under an embankment 240 feet in height. Instruments were installed to provide for measurement of: pressure at the culvert-soil interface, soil pressure within the embankment, deformation of the culvert cross-section, and rotational movement of the culvert footing. Data from periodic readings of the instrumentation are presented. These data are not analyzed in this report. (BPR abstract)
Posey Canyon Arch Culvert Instrumentation
The report discusses the instrumentation of an 8-foot diameter reinforced concrete arch culvert under an embankment 240 feet in height. Instruments were installed to provide for measurement of: pressure at the culvert-soil interface, soil pressure within the embankment, deformation of the culvert cross-section, and rotational movement of the culvert footing. Data from periodic readings of the instrumentation are presented. These data are not analyzed in this report. (BPR abstract)
Posey Canyon Arch Culvert Instrumentation
T. Smith (author) / W. G. Weber (author)
1968
48 pages