A platform for research: civil engineering, architecture and urbanism
Circular tunnel, designed for flow of 15,000 cfs with head of 35 ft is 25 ft in diam, and 1688 ft long; data on design and construction, drilling and blasting, concrete lining using steel forms and tunnel grouting; layout of Maraetai scheme.
Circular tunnel, designed for flow of 15,000 cfs with head of 35 ft is 25 ft in diam, and 1688 ft long; data on design and construction, drilling and blasting, concrete lining using steel forms and tunnel grouting; layout of Maraetai scheme.
Construction of Maraetai diversion tunnel
New Zealand Eng
Macky, J.H. (author)
1950
17 pages
Article (Journal)
English
© Metadata Copyright Elsevier B. V. All rights reserved.
Diversion tunnel and construction arrangement method of diversion tunnel
European Patent Office | 2023
|Construction a diversion tunnel in Hokkaido
Tema Archive | 1999
|Construction of Cobble Mountain diversion tunnel
Engineering Index Backfile | 1933
|